Central Imaging Review in Clinical Trials: How It Works

Central imaging review means that trial scans are read at one centralized facility instead of, or in addition to, the sites that acquired them. For a sponsor or CRO, it is a way to get consistent, blinded and auditable image reads. The review only pays off when the images, the charter and the lab data around them are planned together. That is how we approach imaging at KoHealth Labs: as one part of a unified lab and imaging data package for a study.
If you landed here looking for a patient imaging center, this page is about something different: the research process behind imaging endpoints in drug and biologic trials.
TL;DR
- Central imaging review sends trial images from every site to one facility, where trained readers interpret them under a shared protocol. The FDA says images may be read at the site, at a central facility, or both.
- It helps most when site interpretation varies and image measurements drive eligibility, safety or efficacy endpoints.
- The imaging charter is the backbone: it defines acquisition, transfer, de-identification, reading, archiving and reader qualifications.
- Blinding, reader independence and documented training are what make central reads credible to regulators.
- Imaging data is easier to use when it is standardized and delivered alongside lab data in one structure.
What central imaging review is, and what it is not
In routine care, a radiologist reads a scan to decide what to do for one patient, usually within hours. In a trial, the same scan is also a data point. The FDA’s guidance on imaging endpoints notes that image interpretation, image review and image read are used interchangeably, and that readers are sometimes called image reviewers.
A useful academic comparison of trial and routine imaging, from a review in Imaging in Clinical Trials, lists the differences that matter operationally:
- Response is judged against strict, objective protocol criteria.
- Imaging happens on a protocol schedule, often more frequently than in practice.
- Images are exported to a single location for centralized review.
- Exported data must be fully anonymized and identifiable only by a code.
- Quantitative measurements are subject to audit, which may involve CROs.
Three terms come up constantly:
- Site read: the local investigator or radiologist interprets the scan. It is needed for patient care and often for local safety decisions.
- Central read: a reader at the central facility interprets the same scan under trial rules, usually blinded to treatment arm.
- Imaging core lab: the facility that runs the central process, including image intake, quality checks, reader management and data delivery.
Why sponsors use it
The FDA’s position is that central interpretation may enhance credibility and consistency in open-label trials. It can also limit site-specific image-quality problems and give readers more uniform training, which reduces variability. The guidance adds that how useful it is depends on the role of imaging in the study, how variable it is and the potential for bias. It is not critical in every trial.
A 2013 analysis of the FDA’s stance reports that the agency recommends blinded independent central review where site interpretation is variable and image measurements matter for eligibility, safety or efficacy endpoints. The reasoning is that a central process provides verifiable, uniform reader training and ongoing management of reader performance.
A practical rule of thumb for a trial designer: the more an imaging measurement decides whether a participant enters, stays in or counts as a responder, the stronger the case for a central read.

Typical reads in a central workflow
A neuro-oncology review of read paradigms describes two main read types from an imaging core lab:
- Eligibility reads, which confirm inclusion and exclusion criteria. One example is measurable disease of at least 1 cm × 1 cm on at least two slices no thicker than 5 mm.
- Response reads, which evaluate response or confirm the date of progression.
The most common response paradigm is the locked time-sequential read. The reader sees one time point at a time in chronological order, blinded to how many time points exist, and the assessment is locked after each read. The same review notes that adaptive designs may need central confirmation of progression before a participant switches therapy. Those confirmation reads are often done by a single reader independent of the primary endpoint paradigm.
How images travel from site to reader
The FDA expects an imaging charter to describe the trial-specific methods for acquisition, interpretation, archiving and data transfer. For the transfer step, the guidance asks the charter to specify:
- how technical adequacy is verified at the core facility;
- how sites are queried for missing images and asked for repeats;
- how every received image is logged with patient-specific tracking;
- the transfer format, for example DICOM, the standard file format for medical images;
- removal of all subject-identifying information from images sent through channels vulnerable to a security breach.
All of this is in the FDA guidance on imaging endpoint process standards. Acquisition also varies by modality. Cone-beam CT, a 3D scan that dental teams use to plan implants, is one example of a modality with its own acquisition settings that a charter would need to pin down.
What a good workflow looks like in practice
A U.S. comprehensive cancer center described its centralized imaging data management workflow. Raw data stays on scanners only briefly. Images are transferred and verified locally, with image counts checked. They are then redacted with research identifiers in line with HIPAA before central review.
On the technical side, a validation study of a GCP-compliant imaging management system describes sites exporting DICOM images and the system extracting the DICOM elements that hold personal information to support de-identification.
Before images reach the readers, imaging CROs work with the scientific team so that a full, criteria-based assessment is captured at the site level, as an SNMMI Journal of Nuclear Medicine Technology article describes. Catching a missing sequence at intake is far cheaper than discovering it at the read.
A short checklist for study teams:
- Confirm the acquisition parameters in the charter match what each site’s scanners can do.
- Agree on the transfer format and who verifies completeness.
- Define how de-identification is done and checked.
- Set query timelines for missing or inadequate images.
- Define what the site read feeds into and what the central read feeds into, so the two are never confused.
For a deeper walk through charter content, see our guide on turning FDA guidance into site checks for imaging charters.
Readers, blinding and independence
Central review is only as credible as the people and rules behind it. The FDA guidance expects sponsors to document:
- the number of readers and their qualifications;
- that readers have no other involvement in the trial and no financial conflicts of interest;
- plans for reader fatigue and for substitute readers;
- training materials, display sessions and read testing against prespecified performance criteria.
In a randomized controlled trial, the guidance expects primary-endpoint readers to be blinded to treatment assignment. It anticipates that most imaging-based primary endpoint trials will run with no reader knowledge of individual clinical data. In certain conditions, readers should also be blinded to the acquisition date and to prior imaging observations.
A review of central reading centers states the purpose plainly: standardized, anonymized and objective grading by trained graders who know neither patient characteristics nor treatment arm. It adds that the key workflow steps are audited by sponsors and health authorities. Specialty societies set their own bars as well. The American Society of Echocardiography standards for echo core labs say reader qualifications and training must be specified and documented, including ongoing training and procedures for replacing reviewers.
What it does for timelines and data quality
The FDA lists the upsides: better image quality control, more uniform reader training and performance management, less variability and a more precise estimate of the treatment effect. It also says central interpretation can take longer than the several hours typical in diagnostic practice, so read turnaround belongs in the plan from the start. Build it into the visit schedule and the data cut-off logic, not into a later amendment.
Cost follows the same logic: scope, number of time points, number of readers and adjudication all move it. Our overview of what sponsors and CROs pay for an imaging core lab breaks down those drivers.

What U.S. regulators expect
The FDA’s April 2018 guidance gives nonbinding recommendations to help sponsors optimize imaging data quality when imaging supports a primary endpoint, or a component of one, in drug and biologic trials. It covers acquisition, display, archiving and interpretation process standards. Nonbinding means it describes the agency’s current thinking, so sponsors usually align with it and document any deviations. Confirm the current version on the FDA’s guidance page when you plan a study, because guidance can be revised.
Why the data around the read matters
A central read produces measurements, and those measurements have to land next to labs, visit data and specimen results without manual reconciliation. Two issues cause most of the friction: inconsistent imaging data structure across sites, and unclear traceability from a reported value back to its source. Our guides on imaging data standardization and DICOM SR checks for traceable SDTM mapping go through both. If you are still designing the study, integrating radiology into study design is the earlier conversation to have.
Perspective
We see imaging as one stream of study data, not a separate project. A central read is only as useful as the images that reach it and the data structure it feeds, so the charter, the sites’ acquisition and the delivery format should be settled together.
That is why our model combines laboratory testing, radiology services, specimen pickup and bundled lab and imaging data for clinical research. When imaging and lab data come from one partner, with regulatory-aligned data delivery and EMR integration, sponsors and CROs have fewer hand-offs to reconcile and fewer places for a study to slow down.
Our onboarding and training are built so that sites know what is expected before the first participant is scanned.
Kohealth Labs
How KoHealth Labs supports trials that use imaging
KoHealth Labs serves as a centralized laboratory and supplier partner for clinical trials, supporting pharmaceutical companies, biotechnology organizations, CROs and research sites with laboratory testing, specimen collection and management, and biomarker analysis. Our integrated offering pairs laboratory diagnostics with radiology services and AI-driven, analysis-ready data bundles, plus courier specimen pickup and dedicated onboarding and training.
If you are scoping a study and want imaging and lab data delivered in one coordinated package, start with our clinical trial and research laboratory services.

FAQ
Is central imaging review required for every imaging trial?
No. The FDA says its usefulness depends on the role and variability of imaging in the study and on the potential for bias. It is most often used when image measurements affect eligibility, safety or efficacy endpoints and site interpretation could vary.
Does a central read replace the site read?
Not necessarily. The FDA notes that images may be interpreted at the site, at a central facility, or both. The site read typically supports patient care, while the central read supports the trial endpoint under protocol rules.
What should an imaging charter cover?
It should describe acquisition, interpretation, archiving and data transfer. That includes image verification, handling of missing images, tracking, transfer format and removal of subject-identifying information.
Are central readers told which treatment a participant received?
In a randomized controlled trial, the FDA expects primary-endpoint readers to be blinded to treatment assignment. In most imaging-based primary endpoint trials, readers also have no knowledge of individual-level clinical data.
Sources
- FDA, Clinical Trial Imaging Endpoint Process Standards Guidance for Industry (April 2018)
- Imaging in clinical trials (2010)
- Blinded independent central reviews: The FDA weighs in (2013)
- Radiographic read paradigms and the roles of the central imaging core lab
- Centralized Clinical Trial Imaging Data Management (2019)
- A Good Practice-Compliant Clinical Trial Imaging Management System (2019)
- SNMMI Clinical Trials Network Research Series (2023)
- The role of central reading centers: current practices (2015)
- ASE Standards for Echo Core Labs
- CBCT 3D imaging before implant placement